Product Description
Fluke 3000 FC Series Wireless Multimeter
FREE UPS GROUND SHIPPING
See it. Save it. Share it.
All the facts, right in the field. The Fluke 3000 FC True-RMS Wireless Multimeter with the Fluke Connect™ app and ShareLive™ video call.
With its precision, reliability and ease of use, the Fluke 3000 FC Wireless Multimeter is the ideal solution for professional technicians. Independently tested for safe use in CAT IV 600V/ CAT III 1000 V environments, the Fluke 3000 FC has all the features you need to troubleshoot and repair many problems in electrical and electronic systems.
The Fluke 3000 FC gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 3000 FC provides higher 0.09% basic accuracy, a digital display showing up to three secondary measurements from remote modules, and a bright white backlight.
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting.
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V, Cat IV 600 V; IP54
Plus, the Fluke Connect wireless enabled modules measure AC, DC and AC DC voltage, AC and DC current, plus temperature, all of which display on the Fluke 3000 FC Series Wireless Multimeter. Choose a standard clamp or flexible clamp to measure AC current. Mix and match modules to suit your unique measurement needs. Read the primary measurement on the main display and up to three modules at any one time. Modules are available separately or as part of Fluke Connect kits.
View spec
Range¹ / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2 3 4 45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mV Range / resolution 600.0 mV / 0.1 mV
Accuracy 0.09% + 2
V Range / resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 0.09% + 2
0.15% + 2
))) Range / resolution 600 Ω / 1 Ω
Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω Range / resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / resolution 2.000 V / 0.001 V
Accuracy 1% + 2
µF Range / resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy 1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC
(45 Hz to 1 kHz) Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy 1.5% + 3
mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy 0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy1 0.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Overload protection 1100 V RMS
Input impedance (nominal) > 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance) > 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Overload protection 1100 V RMS
Input impedance (nominal) > 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance) > 60 dB, DC to 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Overload protection 1100 V RMS
Input impedance (nominal) > 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance) > 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection > 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Overload protection 1100 V RMS
Input impedance (nominal) < 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ < 0.7 V DC
< 0.9 V DC
Typical short circuit current < 350 mA
Overload protection 1100 V RMS
Input impedance (nominal) < 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ 2.000 V DC
Typical short circuit current < 1.1 mA
mA Function
Overload protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions ± 12 counts for changes > 350 mS in duration.
AC functions ± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20m
Obstructed, sheetrock wall Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m
Temperature Operating -10°C to 50°C
Storage -40°C to 60°C
Temperature coefficient 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Altitude Operating 2,000 m
Storage 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF EN 61326–1:2006, EN 61326–2–2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
Safety compliance ANSI / ISA 61010–1 / (82.02.01): 3rd edition
CAN / CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010–1: 3rd edition
IEC / EN 61010–1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight 340 g (12 oz)
Not compatible with Fluke CNX test tools