Fluke ii1050 Acoustic Imager

$21,999.99

See more problems. Diagnose them faster.

SKU: FLK-II1050 Categories: , Tag: Brand:

Product Description

Key features

  • Locate and quantify compressed air, gas and vacuum leaks
  • Detect and analyze partial discharge with PDQ Mode™
  • Identify mechanical issues early with MecQ™ Mode
  • Inspect energized equipment from up to 150 m away
  • Generate inspection reports directly on the device

 

The Fluke ii1050 Acoustic Imager gives maintenance and reliability teams a fast way to locate compressed air, gas and vacuum leaks, detect partial discharge, identify mechanical issues, and verify air tightness, all with one acoustic imaging platform.

SoundSight™ Acoustic Imaging Technology combines a 202-microphone array with a visible-light image to show where abnormal sounds are coming from, even in noisy industrial environments. With a 2 kHz to 100 kHz frequency range and detection capability up to 150 m (492 ft) depending on ambient conditions, the ii1050 helps technicians quickly scan equipment and investigate problems from a safe distance.

Purpose-built analysis modes help teams move from detection to action. LeakQ™ estimates leak rate and associated energy cost to help prioritize compressed air repairs. PDQ Mode™ identifies partial discharge sources, estimates discharge probability, and displays real-time PRPD patterns for evaluating electrical assets. MecQ™ helps identify mechanical issues such as bearing defects, friction, and turbulence before they become obvious through vibration, heat, or audible noise.

Choose the ii1050 configuration that fits your inspection needs. In addition to the standard ii1050 Acoustic Imager, available configurations add the Fluke TC03A iSee™ Thermal Camera Attachment for thermal, acoustic, and visible-light inspection in a single workflow. Other configurations add the SB140 SoundBeacon™, which works with Beacon Mode to quickly locate sealing defects during air-tightness inspections. Configurations with Fluke Premium Care are also available, with one- and three-year coverage options.

Whichever configuration you choose, the ii1050 streamlines inspection and documentation with a 7-inch anti-glare touchscreen, 13 MP visible-light camera, 128 GB of storage, asset tagging, notes, action prioritization, and on-device reporting, helping teams find problems earlier and turn inspection results into corrective action faster.

 

Specifications: Fluke ii1050 Acoustic Imager

Key Features ii500 ii1030 ii1050
Sensors
MEM (Microphones) 64 202 202
Frequency band 2 kHz to 52 kHz 2 kHz to 64 kHz 2 kHz to 100 kHz
Detection range1 0.5 to > 70 meters
(1.6 to > 164 feet)
0.5 to > 100 meters
(1.6 to > 393 feet)
0.5 to > 150 meters
(1.6 to > 492 feet)
Field of view (FOV) (typical) 64°x 48°
Nominal frame rate 25 FPS
Built-in digital camera (visible light)
Field of view (FOV) (typical) 64° x 48°
Focus 50 cm to infinity
(20 inch)
Zoom No zoom 3 x digital zoom
Resolution 0.3 MP 13 MP
Display
Size 7″ LCD with backlight 7″ Anti-Glare LCD with backlight, sunlight readable
Resolution 1280 x 800 (1,024,000 pixels)
Touchscreen Capacitive
Acoustic image SoundMap™ acoustic imaging overlay
Image storage
Storage capacity 20 GB 110 GB
Image format Blended visual and SoundMap™   .JPG
Video format Blended visual and SoundMap™   .MP4
Video length Up to 5 minutes
Digital export USB-C for data transfer
Acoustic 
Measurement range (typical) 2 kHz: 15.4 ~ 115.2 dB SPL
19 kHz: 5.6 ~ 102.5 dB SPL
35 kHz: 28.4 ~ 131.1 dB SPL
52 kHz: 41.8 ~ 133.1 dB SPL
20 kHz: -10.4 ~ 122 dB SPL
25 kHz:  -24.7~ 122 dB SPL
31.5 kHz:  -13~ 122 dB SPL
40 kHz: -10.7~ 122 dB SPL
50 kHz: 8~ 122 dB SPL
Auto max/min dB gain Auto Auto or user selectable max dB
Frequency band selection User selectable through user-made presets or manual entry
Capture Mode
Photo Yes Yes Yes
Video Yes Yes Yes
LeakQ™ Leak size scale (1-10) Leak size scale, rate and cost estimation Leak size scale, rate and cost estimation
PDQ Mode™ – – Yes
MecQ™ – – Yes
Beacon Yes, works with Fluke SB140 SoundBeacon™ for airtightness detection.
Thermal – Yes, works with TC03A
Battery
Battery Rechargeable and field replaceable Li-ion battery
Battery life 6 hours (1 x 6hrs) >7 hours (2 x 3.5hrs)
Battery charging time 3 hours <3 hours
Battery charging system External (Bay charger) Internal (USB-C)
Software
Ease of use Intuitive user interface
Acoustics: Show dB scale On/Off
Acoustics: Min/Max dB Min/Max Max dB/Auto
Acoustics: Profiles – Preset capture profiles
Acoustics: High frequency Yes
Acoustics: Multiple sources Single Source Multi Source
Palette: Colors 3: Grayscale, Ironbow, and Blue-Red
Palette: Overly transparency Yes: 1-100 %
Grayscale mode Yes
Trend graphs Frequency and dB scale
Leak values LeakQ TM scale (1-10) Leak costs, Leak volume, LeakQ TM scale (1-10)
Annotation Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure
Photo notes Up to 4 photo notes for reference
Asset inspection status – As left’, ‘As found’, ‘Undetermined’
Asset ID Text input and automatic QR code based asset ID identification
Actions annotation – Action requirement, priortity and notes
On-Device Reporting – Support (PDQ, LeakQ, PDQ+Ti, LeakQ+Ti, Ti mode)
General Specification
Tripod holder / connector – Yes: 1/4″-20
USB 1 x USB-C 2 x USB-C
Wireless – Wi-Fi
Operating Temperature -10 to 45 °C
(14 to 113 °F)
Storage Temperature -20 to 70 °C
(-4 °Fto 158 °F) without batteries installed
Operating altitude Up to 2000 m Up to 2000 m Up to 2000 m
Storage altitude Up to 12000 m Up to 12000 m Up to 12000 m
Relative humidity 10 to 95 % RH, non-condensing
Size (H x W x L) 186 x 322 x 68 mm
(7.3 x 12.7 x 2.7 inches)
235 × 154 × 46 mm
(9.25 × 6.06 × 1.81 inches)
Weight (battery included) 2,1 kg
(4.6 pounds)
1,2 kg
(2.6 pounds)
Ingress Protection (IP) IP40 IP54
Warranty 2 year
Fluke Premium Care Premium Care Standard2
Self-diagnostic notification Array-health test to identify when microphone array needs attention
Supported languages Arabic, Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
OS supported – – –
Safety & Environmental
RoHS compliant Yes
General safety IEC 61010-1: Pollution degree 2
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A3 IEC 61326-1: Industry Electromagnetic Environment, CISPR 11: Group 1, Class A
Korea (KCC) Class A4 Equipment (Industrial Broadcasting & Communication Equipment) Class A Equipment (Industrial Broadcasting and Communication)
USA (FCC) 47 CFR 15 subpart B. This product is
considered an exempt device per clause 15.103
47 CFR 15 subpart
Radio Equipment Directive (2014/53/EU) (RED) – Yes Yes
¹  Depending on ambient conditions
²  Subject to regional availability (www.fluke.com/premiumcare)
3 Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
4 Device meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
image_print

Additional Information

Weight 3 lbs
Dimensions 12 × 8 × 4 in