Fluke 115 True-RMS Multimeter

Fluke 115 True-RMS Multimeter

Fluke 115 True-RMS Multimeter

FREE UPS GROUND SHIPPING

With its simple operation, compact design and ease of use, the Fluke 115 True RMS digital multimeter provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use.  Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V Environments.

 

  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Frequency and capacitance
  • Maximum Voltage ac/dc 600V
  • 10A ac/dc current measurement (20 A overload for 30-seconds max)
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

Safety conformance

All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.

 

Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10 °C to 50 °C
Storage temperature -40 °C to 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Batterylife 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/Resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] [counts]): 0.5% 2
DC volts Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ± ([% of reading] [counts]): 0.5% 2
AC millivolts1 True RMS Range/Resolution 600.0 mV / 0.1 mV
Accuracy 1.0 % 3 (dc, 45 Hz to 500 Hz)
2.0 % 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0 % 3 (dc, 45 Hz to 500 Hz)
2.0 % 3 (500 Hz to 1 kHz)
Continuity Range/Resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of
500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9 % 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5 % 2
Diode test Range/Resolution 2.00 V / 0.001 V
Accuracy 0.9% 2
Capacitance Range/Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% 2
Range/Resolution > 1000 μF
Accuracy 5% 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% 2 typical
AC amps True RMS
(45 Hz to 500Hz)
Range/Resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% 3
20 A overload for 30-seconds max
DC amps Range/Resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.0% 3
20 A overload for 30-seconds max
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50 kHz / 0.01 kHz
Accuracy 0.1% 2
Notes:
¹ All AC voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
² Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
• Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
• Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F.
Mechanical & General Specifications
Size 167 x 84 x 46 mm (6.57″ x 3.31″ x 1.82″)
Weight 550 g
Warranty 3 years