Fluke T6-1000 Electrical Tester with FieldSense, 1000V
Orders over $100 ship free
Now you can measure voltage without test leads. Be safer, faster, more efficient. And be everywhere, testing where it used to be impossible
Measure voltage … without test leads
FieldSense technology lets you slide the open fork over a conductor and see the voltage level.1
- Be safer: Measure voltage to 1000 V ac through the open fork, without test leads.
- Be faster: No need to open covers or remove wire nuts.
- Be more efficient: Simultaneously measure voltage and current.
- Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).
Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage. Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A. It will change your job. Safer. Faster. Easier.
Product Highlights
- FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage
- Simultaneous voltage and current display – shows all power supply measurements at a glance for efficient trouble shooting
- 1 to 1000 V ac or dc (T6-1000)
- 0.1 to 200 A ac
- True-rms voltage and current
- Resistance 1 Ω to 100 kΩ
- Frequency measurement 45 Hz to 66 Hz
- Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
- HOLD button temporarily freezes the reading for easy viewing
- Easy to read display with backlight
- Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
- Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase*
Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations. * Register product online within 45 days of purchase to extend warranty to four years. See http://a.fluke.com/registration for details. Two-year additional warranty offer may be discontinued without notice
Measurement Specifications |
Function |
Requires test leads |
Range |
Resolution |
Accuracy[1] |
FieldSense
ac voltage true-rms |
No |
1000 V |
1 V |
± (3 % 3 counts) 45 Hz – 66 Hz[2][3] |
FieldSense
ac current true-rms |
No |
200.0 A |
0.1 A |
± (3% 3 counts) 45 Hz – 66 Hz |
FieldSense
frequency (Hz) |
No |
45 Hz – 66 Hz |
1 Hz |
± (1% 2 counts)[3] |
Volts ac true-rms |
Yes |
1000 V |
1 V |
± (1.5% 2 counts) 45 Hz – 66 Hz |
Volts dc |
Yes |
1000 V |
1 V |
± (1% 2 counts) |
Resistance |
Yes |
2000 Ω |
1 Ω |
± (1% 2 counts) |
Yes |
20.00 kΩ |
0.01 kΩ |
Yes |
100.0 kΩ |
0.1 kΩ |
Safety |
|
1000 V CAT III
600 V CAT IV |
|
|
Accuracy[1]: ± ( [ % of reading] [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range. |
General Specifications |
Calibration |
1-year calibration cycle |
Dimensions |
61.1 x 259.3 x 43.8 mm |
Jaw opening |
17.8 mm |
Weight |
0.35 kg (0.78 lb) |
Temperature |
Operating |
-10 °C to 50 °C (14 °F to 122 °F) |
Storage |
-30 °C to 60 °C (-22 °F to 140 °F) |
Altitude |
Operating |
2,000 m (6,562 feet) |
Storage |
10,000 m (32,808 feet) |
Relative Humidity |
0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) |
0% to 75%, 30°C to 40 °C (86 °F to 104 °F) |
0% to 45%, 40°C to 50 °C (104 °F to 122 °F) |
Battery Type and Life |
2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense |
Temperature coefficient |
0.1 x (specified accuracy) / °C for <18°C or >28 °C |
0.1 x (specified accuracy) / °C for <18°C or >28 °C |
Safety |
IEC/EN 61010-1: Pollution Degree 2 |
Electromagnetic Environment |
IEC/EN 61326-1: Portable |
Includes:
- Attached test leads with removable 4 mm probe caps
- User documentation